Tuesday, September 30, 2008

How did my Air Conditioner Freeze Up

When a persons Air conditioner freezes up they have a hard time figuring out why, well here are some low tech explanations that I think will make sense to you.
When your air conditioner runs it has a pupose and this purpose is to take the heat out of your house the way it does that is to transfer that heat energy into another substance besides your air, for the purpose of this explanation we will use refrigerant more commonly known by the dupont brand name Freon.
In order for energy to transfer you need to have a temperature difference and when you supply that temperature difference the energy will move from the hot substance to the cooler substance until both are the same temperature. When you put an ice cube in your hand your hand gets cold right? What happens to the poor ice cube, it picks up heat until it can't absorb anymore then you have a wet hand right.
To trasfer the heat energy out of the air in your house we usually use the refrigerant flowing through a series of copper coils pressed together with aluminum fins called an evaporator or indoor coil. With the refrigerant at the right pressure in this coil the corresponding temperature will typically be 38-45 degrees, so that when you draw your 75-80 degree air across it you will pick up heat as we discussed earlier. Because that coil temperature is below what is called the dew point of the air in your house in addition to giving up heat the air will also relieve itself of moisture or precipitate. This moisture travels down the coil to the drain and everything works as it should. When a freeze up occurs a couple of things happen that aren't supposed to.

1. your coil temperature gets below freezing

2. the water that is precipitating out of your air is not water anymore it's ice

There could be a couple of explanations for this
1. The most common reason for a freeze up is your filter is dirty (and you will feel so foolish if you call a service person out to your home and he pulls the dirty filter out and charges you $100 so don't let this happen to you). Your air conditioner is designed for a certain amount of airflow and anything less than that will cause the coil temperature to drop because you air not drawing enough warm air across it to give the refrigerant heat to pick up.

2.The second reason your coil might freeze up is low refrigerant pressure jusst like low airflow not providing enough heat for the system low refrigerant pressure does not provide enough transfer media (refrigerant) for the system the coil temperature drops in the first part of the coil while it rises in the rest of it, but that cold part starts ice and works its way up the coil over time.

These are not the only reasons just the most common. Low airflow may be caused by duct obstructions, a bad fan motor,a coil that is very dirty or too many of the supply grilles closed.
Low refrigerant pressure is caused by leaks or obstructions in the system.

If you want to save money the next time you have a freeze up check these things out.

Monday, September 29, 2008

Homeowner Cries for Help

I have a old White Rodgers Furnace however this year I go to turn my furnace on and the the heat kicks on and off as it should however the blower stays on and refuses to turn off. I learned if i tap the furnace it goes off every time. If the furnace is not on I can put the the Fan in Auto and On and it will turn on and off but not once the Furnace heat kicks it on then I have no control to turn it off. Please any suggestions. Online i read possible sensor or fan limit switch.

It is definitely your fan/limit switch which is a bi metal coil which as it heats and cools of course expands and contracts and as it does that it turns the controller itself and makes or breaks contact. When they fail the coil does not have the strength to turn the wheel as the wheel corrodes and gets dirty. You may be able to lubricate it with spray lubricant and turn the wheel slowly back and forth a couple of times and get it to work, but to get a new one and replace it is a simple operation and very easy to get to. Just make sure you clip the small wire at the bottom because if your fan circuit is 24 volts which it probably is that wire must be cut to prevent sending line voltage to the control side of the transformer.

Sunday, September 28, 2008

When Smoke Gets in your Eyes

I rent an apartment upstairs from the landlord who smokes - we each have our own forced air oil furnace - but I get a smoke smell (cigarette) and occassionaly an oily chemical smell in addition to alot of dust and soot- I'm trying to convince the landlord to get the furnace professionally serviced before this winter - but he says he can't smell anything and isn't keen to look into it. In the meantime i'm trying to work out what would be the best filter for my furnace to cut down on these odors? I have some carbon impregnated register filters but i'm curious whether a electrostatic and carbon filter combo or a merv12 filter would be better?
Thanks.

You are probably not going to make much of an impact with any kind of normal filtration. You will probably have to get a clean effects or something like that utilizing multiple technologies and that may be cost prohibitive in a rental situation. Sorry for the bad news I have just seen too many people spend money and still have the problem they started with.
There are systems used in bars and restaurants that will eliminate most of by products of smoke and VOC's but they are pretty expensive which is why you only see them in nicer places here is a link to one brand http://www.purennatural.com/fs.php?center=smoke-eaters/smokeeater.php there are a few others check for some reviews on line

Saturday, September 27, 2008

Is your air making you sick

The term air conditioning refers to the cooling and dehumidification of indoor air for thermal comfort in buildings and motor vehicles. We usually call them A/C or aircon that keep us comfortable in our indoor environments. Aside from added comfort, air conditioners may cause several health hazards. In fact, the problems associated with air conditioners arise out of overuse.

Air conditioning exaggerates the effects of arthritis and neuritis. It also causes problem for those with sinus trouble, causing their heads to become blocked. In addition to these obvious reactions to an air conditioned environment there are many far more delicate reactions that can adversely affect a person's health.

Studies between those who have worked for prolonged periods in air conditioned offices and those who work outdoors have shown that the people exposed to air conditioning are more prone to colds, flu and other minor ailments. It has also been seen that the body undergoes a certain amount of stress when it is forced to go from a very hot environment into an air conditioned one; eventually this can cause problems.

It is also clear that those who spend too much time in an air conditioned situation are not able to readily cope with hot temperatures. Indeed many people have been made unwell by extreme variances between outside and inside temperatures.

Air conditioners in cars also have some problems. According to a researcher (American Automobile Safety Organisation), extended exposure to car air conditioner may cause drowsiness and not being able to concentrate on driving.

Micro-organisms have been found within the units that may cause breathing problems. Researchers at Louisiana State Medical Center identified eight different types of mold living inside of 22 of 25 cars tested.

Air conditioning units can also circulate air-borne diseases, such as Legionairre's Disease. Without proper filtration or maintenance a typical system will simply recirculate pollutants.

However, spending just a few hours a day in an air-conditioned room is not harmful for one's health. But, if air conditioners are not well maintained, they can cause some very serious problems. A dirty air filter can harbor pollen, fungi and bacteria and allow millions of microorganisms into the room, possibly triggering an asthma attack, irritation of the eyes, nose, and throat — even flu like illness.Some simple maintenance steps will help alleviate these problems. It is better to vacuum the air filter every two to four weeks and then wash it in soapy water. Be sure to let the filter dry completely before reinstalling it.

Thursday, September 25, 2008

Another successful Do It Yourselfer

Sport
Need Help Please Central AC Wires Burning
Noticing my air blowing warm I checked the outside unit. And the 3 wires that connect to my tank (I think my compressor) have burned off completely at the connection. The wires are Red, Black and Yellow. I think a lizard got caught between them so it shorted them out. So I replaced the connectors and AC started up fine. But after about 6 hour AC went out again. I check and its the same thing. Please anything else I can look for or do. really don't have the money for a repairman at this time. Thanks Below are Pictures so you can see and help a little easier.

If you use regular wire terminations they will burn up again it is just a matter of time. You need to purchase compressor wire terminations. Termlok is one brand name, there are others. Go to an HVAC supply house near you pick up terminations and rewire. After you get it wired right replace the contactor and capacitor (cheap insurance) and then clean your outdoor coil and you should be fine, good luck.

I took your advices and everything seem to work out fine. I went to United Refrigeration Inc and purchased the Termlok Connector repair kit (which came with the wires, connector pins with screws) for 34.99. I cleaned the compressor pins of any corrosion (being careful) and connected everthing checking it twice Thanks again for all your help, saved alot of money and headache with waiting on a repair. Thanks again.

Wednesday, September 24, 2008

Commercial Business save everyday you run your Air Conditioner

Smartcool Systems Inc. is an advanced energy conservation solutions company that specializes in energy and cost reduction technologies for commercial and retail businesses. The company's wholly owned subsidiary, Smartcool International Inc., is the owner, developer, manufacturer and worldwide distributor of the Energy Saving Module (ESM)™. This green technology reduces the electricity consumption (Kwh) and maximum demand (KW) of air conditioning and refrigeration compressors. Rather than replacing existing equipment, the ESM™ works in conjunction with existing controls in order to ensure that compressors work at maximum efficiency, while maintaining preset temperature levels and without causing over-cycling. This process, known as "Compressor Optimization" can reduce compressor runtime by more than 30% and electricity consumption and demand by up to 20%.

Rising global energy demand is resulting in significant increases in energy prices. Environmental concerns are causing both government and industry to re-examine the way they do business. With licensed distributors in nine countries and exports to many more, Smartcool provides organizations around the world with solutions to address the growing pressure to reduce energy costs, increase profits and decrease greenhouse gas emissions. Over 25,000 ESM™ units have been installed throughout the world since 1986 and the ESM™ is utilized by some of the worlds leading corporations such as Tesco Supermarkets, Telstra Corporation, and Gate Gourmet, to name only a few.

Tuesday, September 23, 2008

Greencore Solar Air Conditioning

Greencore Technology, Inc., formerly Aquacell Technologies, Inc. announced they had installed Greencore 10200 solar powered DC air conditioner at a metro PCS cell tower site. The Greencore system has replaced one of two 4 ton air conditioners an the cellular base station housing the electronic transmission and data equipment. Initial analysis has demonstrated that the Greencore 10200 provides comparable cooling capacity to the 4 ton unit it replaced.
"We are extremely encouraged by the initial reports we have received on the performance of our solar air conditioner at the metroPCS cell tower site," said Kevin Spence GreenCore's President and Chief Financial Officer. "The power consumption of the traditional air conditioning units used at cell site locations is quite significant, as they have not been designed to conserve energy. Replacing just one of the two air conditioners on cell tower base stations with the GreenCore solar air conditioner will provide significant reduction in grid power consumption and its related cost, in addition to providing emergency cooling capability in the event of a power outage."
The GreenCore solar powered DC air conditioner ( www.greencoreair.com) combines the most efficient photovoltaic technology with DC engineered air conditioning innovation to provide climate control that does not contribute to greenhouse gas emissions and global warming. The system has been designed to efficiently operate completely grid-free or as a hybrid air conditioning unit.